53 research outputs found

    Mesh Exposure and Associated Risk Factors in Women Undergoing Transvaginal Prolapse Repair with Mesh

    Get PDF
    Objective. To determine frequency, rate, and risk factors associated with mesh exposure in women undergoing transvaginal prolapse repair with polypropylene mesh. Methods. Retrospective chart review was performed for all women who underwent Prolift Pelvic Floor Repair System (Gynecare, Somerville, NJ) between September 2005 and September 2008. Multivariable logistic regression was performed to identify risk factors for mesh exposure. Results. 201 women underwent Prolift. Mesh exposure occurred in 12% (24/201). Median time to mesh exposure was 62 days (range: 10–372). When mesh was placed in the anterior compartment, the frequency of mesh exposure was higher than that when mesh was placed in the posterior compartment (8.7% versus 2.9%, P=0.04). Independent risk factors for mesh exposure were diabetes (AOR = 7.7, 95% CI 1.6–37.6; P=0.01) and surgeon (AOR = 7.3, 95% CI 1.9–28.6; P=0.004). Conclusion. Women with diabetes have a 7-fold increased risk for mesh exposure after transvaginal prolapse repair using Prolift. The variable rate of mesh exposure amongst surgeons may be related to technique. The anterior vaginal wall may be at higher risk of mesh exposure as compared to the posterior vaginal wall

    Change in Overactive Bladder Symptoms After Surgery for Stress Urinary Incontinence in Women

    Get PDF
    OBJECTIVE: To assess change in overactive bladder (OAB) symptoms up to 5 years after surgery and to identify associated predictors of change from baseline. METHODS: This is a secondary analysis of data from three multicenter urinary incontinence (UI) surgical trials of women with stress-predominant mixed UI assigned to Burch colposuspension, autologous fascial sling, or retropubic or transobturator midurethral slings. The primary outcome was improvement of 70% or greater from baseline in symptoms measured by the Urinary Distress Inventory-Irritative subscale. Surgical groups were compared within respective trials. Generalized linear models were fit using 1-year and up to 5-year data. RESULTS: Significant improvements in UDI-I scores were reported by each surgical group one year after surgery (p CONCLUSION: Most women with stress-predominant mixed UI experienced significant improvement in OAB symptoms after incontinence surgery although this initial improvement diminished over time. Obesity blunted symptom improvement. LEVEL OF EVIDENCE: II

    The impact of fecal and urinary incontinence on quality of life 6 months after childbirth

    Get PDF
    The objective of the study was to investigate the impact of postpartum fecal incontinence (FI) and urinary incontinence (UI) on quality of life (QOL)

    A multicentered comparison of measurements obtained with microtip and external water pressure transducers

    Full text link
    This study compared simultaneous intravesical pressure readings obtained with catheter-mounted microtip transducers and external water pressure transducer catheters during filling cystometry. Women undergoing multichannel urodynamic testing were randomly assigned to one of three groups: two microtip catheters, two external water pressure transducer catheters, or one of each type. Intravesical pressure was measured simultaneously for each transducer combination in each subject for minimal and maximal Valsalva effort and minimal, moderate, and maximal cough effort at two sequential bladder volumes (150 and 300 ml). Paired t tests were used to compare the means of the intravesical pressure obtained by the two types of catheters. The largest mean differences were observed when comparing microtip and water pressure transducers. Correlations of maximum pressure were consistently high between two microtip transducers and two water pressure transducers but lower for the microtip–water combination. Excellent reproducibility was demonstrated with transducers of similar types for intravesical pressures recorded during Valsalva and cough in women without prolapse. However, considerable variability was seen in pressures recorded by different transducers, particularly dependent on the water catheter manufacturer, indicating that intravesical pressure recordings from microtip and water-based systems are not interchangeable.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/45850/1/192_2005_Article_27.pd
    • …
    corecore